- Model:
-
45-42480297
Details: Advanced Drainage Systems 45 Triplewall Sewer & Drain Pipe, 4" x 10 Ft
Descriptions
The Triple Wall HDPE pipe is triple bonded polyethylene for exceptional pipe stiffness. With smooth inner and outerWalls and a corrugated structural core, this HDPE pipe is designed to have superior pipe stiffness to that of PVC sewer and drain pipe, yet priced to compete.
A smooth inner wall is co-extruded with a corrugated structural core, which is then extrusion laminated with a smooth white outer wall. This construction gives the pipe an unprecedented strength-to-weight ratio.
Applications
- Residential drainage
- Sump pump outlet
- Curtain drains
- Retaining walls
- Irrigation
- Downspout runoff
- Foundation/footer drainage
- Septic leach fields
- Agricultural drain outlets
- Parks & golf courses
Features
- Available in 10° (3 m) lengths
- Diameters are 3" and 4" (75 and 100 mm) with three different hole patterns
- Constructed with bell-and-spigot end for soil-tight joints
- Outer layer provides additional resistance to effects of extended exposure to the sun's heat and ultraviolet radiation
- Long-term performance - no costly maintenance
Benefits
- Triple Wall pipe, made from HDPE, provides strength and allows enough flexibility to withstand freeze/ thaw conditions and continous subzero conditions with cracking or shattering
- Corrosion resistant to acids, alkalies and salts, Will nor rust
- Safe, easy, efficient installations without breaking, splitting or cracking
- Multiple fittings options available
Specifications
Scope
This specification describes 3- and 4-inch (75 and 100 mm) ADS 3000 Triple Wall pipe for use in gravity-flow drainage and leachfield applications.
Pipe Requirements
ADS 3000 Triple Wall pipe shall have a smooth interior and exterior.
- 3- and 4-inch (75 and 100 mm) pipe shall meet the requirements of ASTM F810
- Manning's "n" value for use in design shall not be less than 0.009
Joint Performance
Pipe joints shall be bell-and-spigot. Bell ends shall be integrally formed on the pipe at one end to form a soil-tight connection.
Material Properties
Pipe material shall be high-density polyethylene conforming with the minimum requirements of cell classifications 424410C or E as defined and described in the latest version of ASTM D3350. The material formulation shall include recycled polyethylene.
Installation
For gravity-flow drainage applications, installation shall be in accordance with ASTM D2321 and ADS' recommended installation guidelines with the exception that minimum cover in traffic areas shall be one foot (0.3 m). For leachfield applications, installation shall be in accordance with AST F481 and as regulated by regional, state and local agencies. Proper authorization for specific applications and designs should be obtained prior to installation to ensure suitability in certain locales.