Details: NGP 780S Slimline Automatic Door Bottom with Silicone Seal
Features
- Aluminum alloy 6063, T5 temper
- Synthetic rubber polymer: Siloxane
- Excellent flexibility and memory
- Flame resistant
- Moisture resistant
- Temperature range -100°F to 500°F, remains flexible at extreme temperatures
- Excellent resistance to ozone, UV and aging
- Recommended for areas using FM200 or Halon Fire Suppression Systems
- BHMA Certified to ANSI/BHMA A156.22 performance tests for heat, cold, air infiltration and smoke infiltration
- Mounts on push side of door
- Use with a threshold for maximum sealing capability
- Specify exact net length required to avoid field sizing
- 36" and longer may be cut up to 4" in the field, under 36" should not be cut in the field, order net length
- Available 23" to 96" in length
- End caps furnished standard
- Will work half mortised on swing or sliding doors
- Endurance tested to 5 million cycles
- 1/2" max. drop
- Silicone is gray
- Anodized aluminum
Options
Standards
- CERTIFIED by UL to CAN/ULC-S104 and ANSI/UL10B, complies with NFPA 80 and NFPA 252 for application to Hollow Metal fire doors rated up to 3 Hrs., and Wood fire doors rated up to 90 minutes.
- POSITIVE PRESSURE - CERTIFIED by UL to ANSI/UL10C, complies with IBC, NFPA 80 and NFPA 252 for application to Hollow Metal fire doors rated up to 3 Hrs., and Wood fire doors rated up to 90 minutes.
- AIR INFILTRATION TESTED to ASTM E283, Standard Test Method for Determining Rate of Air Leakage Through Exterior Windows, Curtain Walls, and Doors.
- ACOUSTICAL TESTED to ASTM E90 Standard Test Method for Laboratory Measurement of Airborne Sound Transmission Loss of Building Partitions and Elements, and ASTM E2235 Standard Test Method for Determination of Decay Rates for use in Sound Insulation Test Methods. Refer to information on pages G4 and G5 of our Gasketing catalog for test result data.
- SMOKE & DRAFT CONTROL GASKETING. Certified by UL to ANSI/UL10C and ANSI/UL1784 Category 'H'; complies with IBC and NFPA 105 for use on 'S' labeled Positive Pressure Hollow Metal fire doors rated up to 3 hours, and Wood fire doors rated up to 90 minutes.
- ANSI/BHMA CERTIFIED. Certified Gasketing complies with American National Standard for Door Gasketing and Edge Sealing Systems ANSI/BHMA A156.22 and is listed in the BHMA Certified Products Directory.
Downloads
| Post-Consumer Recycled % | Pre-Consumer Recycled % | |
|---|---|---|
| Aluminum Thresholds, Rain Drip Guards | 18% | 49% |
| Architectural Bronze Thresholds, Rain Drip Guards | 70% | 25% |
| Stainless Steel Thresholds, Rain Drip Guards | 25% | 3% |
| Rubber Ramps | 0% | 0% |
| Gasketing with Aluminum Retainers | 13% | 37% |
| Gasketing with Bronze Retainers | 52% | 19% |
| Gasketing with Stainless Steel Retainers | 19% | 2% |
| Self-Adhesive Gasketing | 0% | 0% |
| Finger Guard 2248 | 13% | 37% |
| Finger Guard 2252 | 0% | 0% |
| Metal Edge/Astragal sets (Steel) | 25% | 3% |
| Lite Kits & Louvers (Steel) | 15% | 5% |
| Aluminum Lite Kits & Louvers | 18% | 49% |
| Stainless Steel Lite Kits | 25% | 3% |
| Continuous Geared Aluminum Hinges | 18% | 49% |
| Stainless Steel Continuous Hinges | 25% | 3% |
Privacy Policy
Loading...