Details: RCI 8310-IQ/8320-IQ IntelliMag For Outswinging Interior or Perimeter Doors

Standard Features

  • Individually encoded armature
  • Illegal armature plate alarm
  • Alarm time setting
  • LSS - Lock Status Sensor (includes LED)
  • Field-selectable voltage - 12⁄24VDC
  • MOV surge protection
  • No residual magnetism
  • Adjustable relock time delay
  • Brushed Anodized Aluminum or Brushed Dark Bronze finish

Plus! Standard Multimag® Features Included

  • Adjustable keyhole mounting
  • Easy access wiring cavity
  • Encapsulated 4-bolt 'Drop-Stop" mounting
  • Self-drilling tek™ fasteners

8320Iq Different Features From 8310Iq

  • Keyhole mounting
  • Easy access wiring cavity
  • Encapsulated 8-bolt 'Drop-Stop" mounting
  • Self-drilling tek™ fasteners
  • For Double Outswinging Doors

Options

Architectural Housing
Order 8330-IQ × 34.5" or
8340-IQ × 46.5" (specify left or right hand)

FUNCTIONAL DESCRIPTIONS
 
Lock Status Sensor Output (LSS)
 
A SPDT relay offers lock status remote indication capability.
LED Indicator
The LED gives a local indication of lock status: red - unsecured; green - secured.
Illegal Armature Plate Alarm
A SPDT relay output offers local LED or remote indication capability of illegal armature alarm.
Alarm Time
Can be set to 15, 30, 60 seconds or manual reset.
Relock Time Delay
Field adjustable relock time delay, 0-90 seconds. Instant release with adjustable relock time.
Timer starts when power is applied.
Non-volatile EEPROM
Will save the armature plate ID, even when power has been removed.

Specifications

Housing Dimensions

1⅝" D × 2 ⅞" W × 10½" L (41.3mm × 73.0mm × 266.7mm)
Including ¼" (6.4mm) mounting bracketArmature Plate Dimensions:
Encoded ⅝" D × 2⅜" W × 7-7⁄16" L
(15.9mm × 60.3mm × 188.9mm)

Voltage:
Field selectable 12⁄24 VDC
Tolerance ±10%

Power/current Requirements

Max 0.59A at 12 VDC
Max 0.29A at 24 VDC

Output Relays:
Lock Status Output (LSS), SPDT 2A @ 30 VDC
Alarm Status Output, SPDT 2A @ 30 VDC

Wiring Requirements:
2 wires - power input
4 wires - relays output

Operating Temperature:
14° to 140° F (-10° to 60° C)

Holding Force:

One-point locking

(up to 1500 pounds)