- Model:
-
8310-42213411
-
Details: RCI 83 Multimag For Outswinging Interior or Perimeter Doors
8310x28 Ships SAME BUSINESS DAY (699-002)
STANDARD FEATURES
- Larger (Right Angled) <a href="http://www.rutherfordcontrols.com/media/19713/8310withled.jpg" class="resource" target="apo_resource">Led</a> size for better visibility (SCS versions only)
- Built-in time delay (instant release with adjustable relock, programmable from 0-110 seconds)
- Field selectable voltage - 12⁄24VDC
- MOV surge protection
- No residual magnetism
- Low energy consumption
- Hardened steel armature nut
- Brushed Anodized Aluminum or Brushed Adonized Dark Bronze finish
Plus! Standard Multimag® Features Included
- Adjustable keyhole mounting
- Convenient plug-in wiring terminals
- Easy access wiring cavity
- Encapsulated 4-bolt 'Drop-Stop" mounting
- Self-drilling tek™ fasteners
OPTIONS
DSS - Door Status Sensor (Retrofit Kits Available)
SCS - Security Condition Sensor with Led
DSS/SCS - Door Status Sensor/Security Condition Sensor Combination with Led
- FUNCTIONAL DESCRIPTIONS
| Security Condition Sensor (SCS) |
- Electronic field presence sensor for remote and local LED indication of lock status (locked or unlocked), reduced holding force caused by materials between magnet and plate, and unlocked device due to current loss.
- Door Status Sensor (DSS)
- Ceramic magnet-reed type sensor for remote indication of door status (opened or closed, independent of
local power); magnet embedded in armature for tamper resistance; reed switch inside electronic
housing cavity for easy access. - Led Indicator
- Included on SCS options, the Led gives a local indication of lock status: red - unsecured; green - secured.
- Low-Voltage Detection
(SCS version only) - Low voltage dramatically reduces electromagnetic lock holding force. This detection feature signals the SCS
relay/LED to activate (alarm) when voltage drops below 10.3 VDC (12V input) or 20.5 VDC (24V input).
Specifications
Housing Dimensions:1⅝" D × 2 ⅞" W × 10½" L (41.3mm × 73.0mm × 266.7mm)
Including ¼" (6.4mm) mounting bracket
Armature Plate Dimensions:
Standard -⅝" D × 2⅜" W × 7-7⁄16" L* (15.9 × 60.3 × 188.9mm)
Optional -⅜" D × 2⅜" W × 7-7⁄16" L* (9.5 × 60.3 × 188.9mm)
DSS armature plate dimensions:
⅝" D × 2⅜" W × 10" L (15.9 × 60.3 × 254.0mm) and
⅜" D × 2⅜" W × 10" L (9.5 × 60.3 × 254.0mm)
Voltage:Field selectable 12⁄24 VDC
Tolerance ±10%
Power/Current Requirements:
Max 0.28A at 12 VDC
Max 0.28A at 24 VDC
Output Relays:SCS (with Led) - SPDT 1.25A @ 24VDC
DSS - SPDT 0.20A @ 12VDC and 0.12A @ 24VDC
Wiring Requirements:2 wires - power input
Up to 4 wires output
Adjustable Time Delay:0 to 110 seconds
Operating Temperature:14° to 140° F (-10° to 60° C)
Certification

Holding Force:One-point locking (up to 1500 pounds)
NOTE: RCI recommends frame reinforcement and our filtered, regulated DC voltage 10 Series power supplies.